Quick answer
- Test for a blocked range hood duct by comparing airflow at the hood with filters in and out, then feeling for airflow at the exterior cap with the fan on high.
- If the hood roars but little air comes out outside, the blockage is somewhere between the hood collar and the exterior cap.
- The most common blockages are a stuck backdraft damper, a bird or rodent nest, crushed flexible duct, and heavy grease buildup.
- A duct that is disconnected in the attic or wall can look like a blockage because air never reaches the outside, and it also breaks code.
- Call a pro for grease buildup you can see in the duct, runs you can't reach, or any roof work you aren't comfortable doing.
Safety first
Turn off power at the breaker, not only at the hood's switch, before you open the hood or touch wiring. Let the motor and lights cool. If you smell burning, see scorch marks, or any step needs gas, roof or electrical work you're not comfortable with, stop and call a licensed pro.
To check if your range hood duct is blocked, run the hood on high and feel for strong airflow at the outside cap. If the fan sounds normal but little air comes out, something between the hood and the cap is in the way. The checks below narrow it down in order, starting from the cheapest and most common causes.
Before you blame the duct, clean the grease filters and confirm the fan is spinning at full speed. Filters cause most weak suction, and the full list of causes is in our weak suction guide. This page picks up once you suspect the duct itself.
Quick diagnosis
| Symptom | Likely cause | Fix |
|---|---|---|
| Weak airflow at the cap, flap barely moves | Stuck damper at the collar or cap | Free or clean the damper |
| Chirping, scratching, twigs at the cap | Bird or rodent nest | Remove nest, add a guard |
| Suction dropped after attic or roof work | Crushed or kinked flex duct | Straighten or replace with rigid duct |
| No air at the cap at all, attic smells like cooking | Disconnected duct | Reconnect and seal joints |
| Airflow dropped slowly over years | Grease buildup in duct | Professional cleaning |
| Weak airflow since installation | Duct too small, too long, too many elbows | Redesign the run |
Test 1: Compare airflow with filters out
This tells you whether the restriction is in the filters or further up.
- Clean the filters, reinstall them, and turn the hood on high.
- Hold a tissue a few inches below the filters. It should pull up firmly and stick.
- Remove the filters and repeat. With a clear duct, the pull gets somewhat stronger but not dramatically.
- If the tissue barely moves even with filters out and the fan clearly spinning, the restriction is past the fan: in the damper, duct or cap.
Test 2: Check airflow at the exterior cap
- Find where the duct exits. Wall caps are usually on the outside wall behind or near the kitchen; roof caps sit above the kitchen or near the chimney chase.
- Have someone turn the hood on high.
- At a wall cap, hold your hand or a tissue near the opening. You should feel a steady stream and see the flap open. A 300–400 CFM hood through a 6” duct produces a noticeable breeze.
- For a roof cap, watch from the ground with binoculars if you can see the flap, rather than climbing. If you must go up, follow the ladder safety steps in our vent flap stuck guide.
Strong airflow at the cap means the duct is clear and the problem is at the hood. Weak or no airflow means keep going.
Test 3: Inspect the damper at the hood collar
Many hoods have a backdraft damper where the duct connects on top of the hood. Grease can glue it shut, or tape from installation can pin it down.
Turn off power at the breaker, not only at the hood’s switch.
- Remove the filters and, if needed, the inner cover or blower housing so you can see up into the collar.
- Shine a flashlight up. You should see one or two flaps that swing freely when you push them with a finger.
- If a flap is stuck, wipe the hinge with hot, soapy water until it moves freely. Remove any leftover packing tape or foam.
- Make sure the flap isn’t reversed; it should open upward, in the direction of airflow.
Test 4: Look up the duct
- With filters and cover off, look up through the collar with a flashlight.
- For a better view, feed an inspection camera up the duct, or hold your phone up in video mode with the flashlight on.
- Look for:
- Nesting material: twigs, grass, feathers, insulation fluff.
- A brown or amber coating on the duct walls, which is grease.
- A sharp kink, collapsed section, or daylight showing through a joint.
Short, straight runs can often be seen end to end. Runs with elbows usually can’t, so move on to the attic or exterior check.
Test 5: Follow the duct in the attic or soffit
If your duct goes through the attic, a short visual inspection there finds a lot of problems.
- Take a flashlight and step only on joists or boarded floor.
- Follow the duct from the kitchen ceiling to the roof or wall.
- Check for:
- Crushed or kinked flexible duct. Storage boxes, insulation, or a person stepping on it can flatten it.
- A disconnected joint. The duct may have slipped off the collar or cap, blowing kitchen air into the attic. The IRC requires kitchen exhaust to go outdoors, not into the attic (M1503.3).
- Sagging runs. Low spots collect grease and condensation.
- Cloth duct tape that has dried and let go.
How to clear the most common blockages
Stuck damper at the cap
A painted-shut, iced or grease-glued exterior flap is common. The vent flap stuck guide covers wall and roof caps.
Nest or debris
- From outside, remove the cap’s screws or guard if it has one.
- If you see eggs or young birds, stop and call a wildlife removal pro; some nesting birds are protected.
- Pull out nesting material with gloved hands or a grabber tool.
- From inside, push a dryer vent brush up the duct to loosen anything further in, then pull debris out at the cap.
- Reinstall the cap and fit a guard with openings around ½”, which keeps birds out without clogging as fast as fine screen.
Crushed or disconnected duct
- Reshape lightly crushed rigid duct by hand if it isn’t creased. Replace creased sections.
- Replace flexible foil duct with smooth rigid metal duct. The IRC calls for galvanized steel, stainless steel or copper ducts (M1503.4).
- Reconnect joints so the upstream section slides inside the downstream one, in the direction of airflow.
- Seal joints with foil tape. Don’t use screws that poke into the duct; they catch grease.
Grease buildup
Light film near the collar can be wiped with hot, soapy water. Anything thicker is a fire hazard and a job for a duct cleaning pro. See grease in ductwork for what’s involved.
When the “blockage” is the duct design
If nothing is physically blocking the duct but airflow has always been weak, the run itself may be the problem.
| Design issue | Rule of thumb |
|---|---|
| Duct too small | 6” round up to about 400 CFM; 7–8” for 600 CFM; 8–10” above that |
| Reduced below the collar | Never reduce duct size below the hood’s collar |
| Too many elbows | Each 90° elbow ≈ 10–15 feet of straight duct |
| Run too long | Aim for under 30 equivalent feet |
| Flexible foil duct | Replace with smooth rigid metal |
Example: 12 feet of straight duct plus two 90° elbows counts as roughly 32–42 equivalent feet, already past the target. Plug your cooktop and duct size into the CFM calculator to see whether the hood and duct are matched.
When to call a pro
- Grease buildup you can see beyond arm’s reach, or thick deposits anywhere.
- Roof caps on steep, high or wet roofs.
- Live animals, eggs, or young in the duct.
- Ducts inside finished walls or ceilings with no access.
- Rerouting or resizing the duct, which may need a permit; check with your local building department.
A duct cleaning or vent service call is typically $150–400 in the US; rerouting ductwork costs more depending on access.
Bottom line
Feel for air at the cap first. If it’s weak, check the collar damper, look up the duct, and follow it through the attic. Most blockages turn out to be a stuck flap, a nest, or a crushed section of flex duct, and all three are fixable in an afternoon.
What you'll need
- Bright flashlight
- Tissue or a strip of paper towelFor airflow tests
- Inspection camera (borescope)Optional; a phone-connected camera on a flexible cable reaches several feet into a duct
- Screwdriver set and nut driver
- Flexible duct brush kitOptional; the kind sold for dryer vents, with rods that screw together
- Foil tapeFor resealing joints, not cloth duct tape
Not sure your hood is big enough? Get a CFM, width and duct size recommendation for your cooktop and kitchen in under a minute.
Open the CFM calculatorFrequently asked questions
How do I know if my range hood vent is clogged?
The fan sounds normal but smoke still escapes, and you feel little or no air at the exterior cap with the hood on high. A tissue held to the hood's intake that barely moves with clean filters is another strong sign.
Can a range hood duct get clogged with grease?
Yes. Grease that gets past the filters coats the duct walls, especially in flexible or ribbed duct and long runs. It restricts airflow and is a fire risk, so thick buildup should be cleaned by a pro.
How long can a range hood duct run be?
Keep it as short as possible, ideally under about 30 equivalent feet, counting each 90-degree elbow as roughly 10–15 feet of straight duct. Longer runs cut airflow noticeably.
Can a range hood vent into the attic?
No. The IRC requires kitchen exhaust to discharge outdoors, not into an attic, crawl space or inside the building (M1503.3). A duct that ends in the attic needs to be extended to a proper roof or wall cap.
Related guides
Range Hood Not Venting? 9 Causes of Weak Suction and Fixes
Why your range hood has weak suction and how to fix it: clogged filters, a stuck damper, blocked or undersized ducts, missing makeup air and more.
TroubleshootingRange Hood Vent Flap Stuck? How to Free Wall and Roof Caps
Range hood vent flap stuck or not opening? Fix painted-shut, greasy, iced or bent flaps on wall and roof caps, clear clogged guards, and stay safe on a ladder.
TroubleshootingGrease Buildup in Range Hood Ductwork: Fire Risk and Cleaning
How grease builds up in range hood ducts, the signs to look for, what to do in a hood or duct fire, and when to clean it yourself or hire a professional.
Compare300 vs 400 vs 600 CFM Range Hood: How Much Do You Need?
300 vs 400 vs 600 CFM range hoods compared: sizing rules with worked examples, the 400 CFM makeup air threshold, noise, duct size and cost at each level.
General information only. Range hoods differ by model, so your owner's manual and local building code come first. HoodWise is independent and brand-neutral; we don't accept payment for coverage. Some links may be affiliate links (disclosure). Last reviewed September 27, 2026.